Sample Mold Report

 prepared for: test address:

Gumpher Home Inspection PA 17033

Detailed Mold Report (NAMES IN RED ARE WATER-INDICATING FUNGI)

Analysis Method Air Analysis Air Analysis Air Analysis Surface Analysis

Lab Sample # 52132844-1 52132844-2 52132844-3 52132844-4

Sample Identification 23809121 23811596 23810133 B1397250

Sample Location 2nd BEDROOM BATH BASEMENT BATH CEILING

Sample Type / Metric Air-O-Cell/75.0L Air-O-Cell/75.0L Air-O-Cell/75.0L Bio-Tape

Analysis Date Fri May 05, 2017 Fri May 05, 2017 Fri May 05, 2017 Fri May 05, 2017

Determination NORMAL NORMAL NORMAL GROWTH

Fungal Types Identified Raw

Count

Spores /

m3

% of

Total

Raw

Count

Spores /

m3

% of

Total

Raw

Count

Spores /

m3

% of

Total

Mold

Present

*INDOOR PROBLEM FUNGI

Cladosporium --- --- --- --- --- --- --- --- --- X

Hyphae --- --- --- --- --- --- --- --- --- X

**Non-Problem Fungi

Ascospores --- --- --- 1 13 7 3 40 5 ---

Basidiospores 1 13 50 4 53 28 1 13 1 ---

Cladosporium 1 13 50 8 106 57 25 333 42 ---

Epicoccum --- --- --- --- --- --- 1 13 1 ---

Penicillium/Aspergillus --- --- --- --- --- --- 20 266 33 ---

Smut/Myxomycetes --- --- --- 1 13 7 8 106 13 ---

Unclassified Pigmented Spores --- --- --- --- --- --- 1 13 1 ---

Total Spore Count 2 26 100 14 185 100 59 784 100 N/A

Minimum Detection Limit 14 14 14 N/A

Comments/Definitions

Raw Count: Actual number of spores

observed and counted.

Spores/m3: Spores per cubic meter.

% of Total: Percentage of a particular

spore in relation to total number of

spores.

X: Spore type was observed.

---: Spore type was not observed.

Mold counts are within a

NORMAL RANGE and there is

no indication, based on the

mold counts, that there is any

exposure concern to the

occupants. The LIGHT DEBRIS

present in the sample likely had

no effect on the accuracy of the

mold count.

Mold counts are within a

NORMAL RANGE and there is

no indication, based on the

mold counts, that there is any

exposure concern to the

occupants. The LIGHT DEBRIS

present in the sample likely had

no effect on the accuracy of the

mold count.

Mold counts are within a

NORMAL RANGE and there is

no indication, based on the

mold counts, that there is any

exposure concern to the

occupants. The LIGHT DEBRIS

present in the sample likely had

no effect on the accuracy of the

mold count.

Presence of current or former

MOLD GROWTH observed.

EXPOSURE TO SPORES

LIKELY and will continue if the

growth is not removed. An

active or intermittent water

source will cause the mold to

continue to grow if the water

source is not eliminated.

* Indoor Problem Fungi are generally capable of growing on wetted building materials.

** Non-Problem Fungi are less capable or do not grow on wetted building materials. They are commonly found in the air outside and infiltrate

into indoor air naturally. High numbers of any one of these spore types as compared to the Control sample may indicate that they are growing on

wetted building materials indoors.

Spore types not listed in this report were not observed.

Background debris estimates the amount of non-spore particles. Increasing amount of debris will affect the accuracy of the spore counts. Total


 This is one page out of seven, but shows the detail and how the results are listed. The lab we work with is very good at next day turn around listing the results.


We are equipped with the latest envonair suction sample pump which is certified calibrated to and exceeding the state mandates. We are also equipped with the hermetically  sealed swab and adhesive slide samples. Providing our clients with absolutely secure chain of custody for each sample taken.



SAMPLE CHAIN OF CUSTODY DOCUMENT THAT FOLLOWS ALL SAMPLES SUBMITTED 

 c o m p a n y a ccou n t cod e W E A THEr : F OG R A I N SNOW W I N D

R / H

T E M P

L IG H T

MODER A TE

Clear

condition s

Client N A M E: A DDR ES S: CIT Y : STATE: ZIP:

RECOMME N DED FLOW RATE & S A M PLIN G TIMES Sample Type Analysis Codes

s e n d to: 3 301 n w 55 th s t . , f t l aud e r d ale, f l 3 3 3 0 9

s a m ple serial # collection loc a tion s

a i r -o-cell/ a l le rgenco- D :

Total volume recommendations: st - spore t r a p types: a ir -o-cell, Allerge n co, etc.

t - tape/bIo-ta pe

A S - Asbestos

B - Bu l k

L P - Lead Paint

SW - Swa b

 W - Water

S C - SWAB COUNT

T C - TAPE COUNT

tot a l 

v olum E

s a m ple

type cod e

Sampled BY: Released By: 

resu l t s a l w a y s a v ail a ble a t w w w . i n s pecto r l a b . c o m

d o not write in this are a

c op yright 2015 . a l l rights rese

Created by Susan Gumpher any and all work or images may not be reproduced without written consent